Signal conditioning

Components

Controllers

Indicating instruments

Overvoltage protection instruments

Separating instruments

Software

Wireless communication

Bluetooth USB adapter

Bluetooth USB adapter for adjustment software

wireless connection from a PC/notebook to a VEGA device with integrated Bluetooth

Your benefit

  • Wireless adjustment of sensors and instruments via Bluetooth with PC and adjustment software PACTware
  • Simple use through USB connection

DTM Collection and PACTware

Open adjustment software with device description and adjustment interface according to the FDT standard

Application area

PACTware is a multi-manufacturer supported software frame for the DTM-based setup, adjustment, diagnosis and documentation of field devices. The VEGA DTMs connect to both field devices and controller, which show the complete device capability in an easy to use and understand graphical format. PACTware supports the DTMs of different manufacturers and operates across multiple communication protocols. This means communication-independent adjustment of different field devices made by other manufacturers is available to all. PACTware and the VEGA DTM is available as a free-of-charge download, see details and links below or go to our download section and search under Software.

Your benefit

  • User-friendly and unique adjustment program for the PC
  • High adjustment comfort through graphic user guidance, project memory and documentation
  • Optimized PACTware DC setup to get the maximum efficiency out of point-to-point connections with minimum effort

LoRa Gateway

LoRa-Gateway for use with VEGA LoRaWAN sensors

Application area

The LoRa-Gateway receives via LoRaWAN the measurement and diagnosis data of appropriately configured VEGA LoRaWAN sensors. The Gateway merges the received data and transmits them via mobile radio to the VEGA Inventory System. The transmission of measured values and messages is carried out via the GSM/GPRS/UMTS/LTE network. The Gateway is available in two versions: - Indoor version for use in offices and living rooms - Outdoor version for use in harsh environments such as workshops and factory halls and for outdoor use

Your benefit

  • No setup required due to preconfigured hardware
  • Quick and easy implementation of the fall back strategy with LoRaWAN, if no mobile phone connection is available

Magnetic pen for display/adjustment module PLICSCOM

Application area

The magnetic pen offers the possibility of easy operation for the display and adjustment module PLICSCOM with the option of Bluetooth/magnetic pen adjustment with closed housing lid with inspection window.

Overvoltage protection B 53-19

Overvoltage arrester for the signal cable of conductive probes

for conductive probes

Application area

The overvoltage arrester B53-19 limits excess voltage. It protects the electronics of the connected probe effectively against the influences of overvoltages.

Your benefit

  • Simple installation through carrier rail mounting
  • High reliability even with impermissible excess voltages

Overvoltage protection B 61-300

Overvoltage arrester for supply and control cables

for supply and control cables

Application area

The overvoltage arrester B61-300 limits excess voltage on supply cables. The arrester protects the electronics of the connected instruments effectively against overvoltages.

Your benefit

  • Simple installation through carrier rail mounting
  • High reliability even with impermissible excess voltages

Overvoltage protection B 61-300 FI

Overvoltage arrester for supply and control cables

for supply and control cables with FI protective circuit

Application area

The overvoltage arrester B61-300 FI limits excess voltage on supply cables. The arrester protects the electronics of the connected instruments effectively against overvoltages.

Your benefit

  • Simple installation through carrier rail mounting
  • Suitable for use in circuits with fault-current circuit breaker
  • High reliability even with impermissible excess voltages

Overvoltage protection B 62-30 W

Overvoltage arrester in two-wire technology for Profibus PA and Foundation Fieldbus circuits

for Profibus PA and Foundation Fieldbus circuits

Application area

The overvoltage arrester B62-30 W limits excess voltage on bus cables. The arrester protects the electronics of the connected instruments effectively against overvoltages.

Your benefit

  • Simple installation through carrier rail mounting
  • High reliability even with impermissible excess voltages
  • Specifically designed for the requirements of Profibus PA and Foundation Fieldbus applications

Overvoltage protection B 62-36 G

Overvoltage arrester for supply and signal cables in 4 … 20 mA circuits

for two-wire circuits

Application area

The overvoltage arrester B62-36 G limits excess voltage in supply and signal cables. The arrester protects the electronics of the connected instruments effectively against overvoltages.

Your benefit

  • Simple installation through carrier rail mounting
  • High reliability even with impermissible excess voltages

Overvoltage protection B 63-32

Overvoltage arrester in two-wire technology for Profibus PA and Foundation Fieldbus circuits

for Profibus PA and Foundation Fieldbus circuits, direct mounting in the cable entry of the field device

Application area

The overvoltage arrester B63-32 limits excess voltage in bus cables. The arrester protects the electronics of the connected instruments effectively against the effects of overvoltages.

Your benefit

  • Simple mounting of the cable gland of the field device
  • High reliability even with impermissible excess voltages

Overvoltage protection B 63-48

Overvoltage arrester in two-wire technology in 0/4 … 20 mA circuits

for two-wire circuits, direct mounting in the cable entry of the field device

Application area

The overvoltage arrester B63-48 limits excess voltage in signal cables. The arrester protects the electronics of the connected instruments effectively against the effects of overvoltages.

Your benefit

  • Simple mounting of the cable gland of the field device
  • High reliability even with impermissible excess voltages

Overvoltage protection B 81-35

VEGABAR 80, VEGAFLEX 80, VEGAPULS 60, VEGADIS 82

Pluggable overvoltage protection for supply and signal cables

Your benefit

  • High reliability even with impermissible excess voltages
  • Integrated version in plics® sensor housing saves separate installation
  • Universal use for sensors with 4 … 20 mA, Profibus PA and Foundation Fieldbus interface