Signal conditioning

Components

Controllers

Indicating instruments

Overvoltage protection instruments

Separating instruments

Software

Wireless communication

VEGAMET 624

Controller and display instrument for level sensors

Controller for a 4 ... 20 mA/HART sensor

Application area

The VEGAMET 624 controller powers the connected 4 … 20 mAA/HART sensor, processes and displays the measured values. The VEGAMET 624 is ideal for simple control tasks in level, gauge and process pressure measurements. For inventory management in remote storage silos, interfaces for simple remote data transmission are integrated. Comprehensive adjustment functions enable individual adaptations to the respective application.

Your benefit

  • Simple data recording and history retrieval from instruments with digital interface
  • Simple integration into the Intranet/Extranet through integrated Web server
  • Steady utilization of the pumps through integrated pump management

VEGAMET 625

Controller and display instrument for level sensors

Controller for two HART sensors

Application area

The VEGAMET 625 controller powers the connected HART sensor, processes and displays the measured values received through HART Multidrop. The VEGAMET 625 is ideal for simple control tasks in level, gauge and process pressure measurements. For inventory management in remote storage silos, interfaces for simple remote data transmission are integrated. Comprehensive adjustment functions enable individual adaptations to the respective application.

Your benefit

  • Simple data recording and history retrieval from instruments with digital interface
  • Simple integration into the Intranet/Extranet through integrated Web server
  • Versatile use through three scalable current outputs for control of indications and connected systems such as e.g. a PLC

VEGAMET 841

Robust controller and display instrument for level sensors

For one 4 ... 20 mA sensor

Application area

1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 841 controller feeds the connected 4 ... 20 mA sensor, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs and totalizers. With VEGAMET 841, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Clearly arranged, readable from a distance and individually programmable display
  • Complex programming of control tasks is no longer necessary
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 841

Robust controller and display instrument for level sensors

For one 4 ... 20 mA sensor

Application area

1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 841 controller feeds the connected 4 ... 20 mA sensor, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs and totalizers. With VEGAMET 841, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Clearly arranged, readable from a distance and individually programmable display
  • Complex programming of control tasks is no longer necessary
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 842

Robust controller and display instrument for level sensors

For two 4 ... 20 mA sensors

Application area

2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 842 controller feeds the connected 4 ... 20 mA sensors, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers, difference, sum and average value calculations. With VEGAMET 842, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 842

Robust controller and display instrument for level sensors

For two 4 ... 20 mA sensors

Application area

2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 842 controller feeds the connected 4 ... 20 mA sensors, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers, difference, sum and average value calculations. With VEGAMET 842, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 861

Robust controller and display instrument for level sensors

For one 4 … 20 mA/HART sensor

Application area

1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 861 controller feeds the connected 4 ... 20 mA or HART sensor, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers and data loggers. With VEGAMET 861, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 861

Robust controller and display instrument for level sensors

For one 4 … 20 mA/HART sensor

Application area

1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 861 controller feeds the connected 4 ... 20 mA or HART sensor, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers and data loggers. With VEGAMET 861, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 862

Robust controller and display instrument for level sensors

For two 4 … 20 mA/HART sensors

Application area

2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 862 controller feeds the connected 4 ... 20 mA or HART sensors, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers, data loggers, difference, sum and average value calculations. With VEGAMET 862, limit values can be monitored reliably and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 862

Robust controller and display instrument for level sensors

For two 4 … 20 mA/HART sensors

Application area

2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 862 controller feeds the connected 4 ... 20 mA or HART sensors, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers, data loggers, difference, sum and average value calculations. With VEGAMET 862, limit values can be monitored reliably and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGASCAN 693

Controller for up to 15 HART sensors

Measured value indication and remote enquiry of measured data for up to 15 HART sensors

Application area

The VEGASCAN 693 is a controller and display instrument for up to 15 HART sensors. It processes the measured values received via HART multidrop and displays the values. Hence measurement results from level, gauge and process pressure measurements can be easily made available to control systems, visualizations and the remote data transmission. Interfaces and functions for the connection to networks and the remote data transmission are integrated. It is particularly suitable for applications in the local and global inventory management.

Your benefit

  • Data recording of up to 200,000 measured values ​​for devices with digital interface
  • Simple integration into the Intranet/Extranet through integrated Web server
  • Measured value and message transmission via e-mail and SMS and data transmission to WEB-VV

VEGASTAB 690

Power supply unit for power supply of two analogue sensors

Voltage supply of two analogue sensors

Application area

VEGASTAB 690 is a power supply unit for independent power supply of two 4 … 20 mA sensors/circuits.

Your benefit

  • Integrated interlock diode for interruption-free connection of a measuring instrument
  • High reliability due to short-circuit proof circuits
  • Trouble-free operation with two galvanically isolated supply circuits