Conductive

EL 1

Conductive rod probe

Rod electrode with PTFE insulation

Application area

Rod electrode with a rod up to 4 m long. Extended temperature range through PTFE insulation. A VEGATOR 130 series controller is required for operation.
The rod electrode EL 1 is a universal level switch for conductive liquids. The instrument is ideal as overfill and dry run protection in conjunction with VEGATOR 131 or VEGATOR 132 controllers.

Your benefit

  • Simple installation in narrow space applications through small sensor dimensions
  • Low maintenance costs through robust design
  • High flexibility through shortenable probe

EL 3

Conductive multiple rod electrode

Rod electrodes with PTFE insulation

Application area

With 2 to 5 rods, a corresponding number of switching points between 5 cm and 6 m can be realized. Extended temperature range through PTFE insulation. A VEGATOR 130 series controller is required for operation.
The multiple rod electrode EL 3 is a universal level switch for conductive liquids. The instrument is ideal as overfill and dry run protection or pump control in conjunction with VEGATOR 132 controllers.

Your benefit

  • Simple setup with minimum time and cost expenditure
  • High flexibility through shortenable probe
  • Maintenance-free through robust design

EL 4

Conductive multiple rod electrode

Rod electrodes with PP insulation

Application area

With 2 to 5 rods, a corresponding number of switching points between 10 cm and 4 m can be realized. A VEGATOR 130 series controller is required for operation.
The multiple rod electrode EL 4 is a universal level switch for conductive liquids. The instrument is ideal as overfill and dry run protection or pump control in conjunction with VEGATOR 132 controllers.

Your benefit

  • Reliable pump control through multiple rod probe
  • Reduced stockkeeping through exchangeable rod probes
  • High flexibility through shortenable probes

EL 6

Conductive multiple cable electrode

Cable electrodes with FEP insulation

Application area

With 2 to 5 cables, a corresponding number of switching points between 22 cm and 60 m can be realized. A VEGATOR 130 series controller is required for operation.
The multiple cable electrode EL 6 is a universal level switch for conductive liquids. The instrument is ideal as overfill and dry run protection or pump control in conjunction with VEGATOR 132 controllers.

Your benefit

  • Reduced stockkeeping through exchangeable cable probes
  • High flexibility through shortenable cable probes
  • Economical pump control through multiple cable probe

EL 8

Conductive rod probe

Rod electrodes with PE insulation

Application area

Rod electrode with a rod up to 3 m long. A VEGATOR 130 series controller is required for operation.
The rod electrode EL 8 is a universal level switch for conductive liquids. The instrument is ideal as overfill or dry run protection in conjunction with VEGATOR 131 or VEGATOR 132 controllers.

Your benefit

  • Simple installation in narrow space applications through small sensor dimensions
  • Price-favourable level detection
  • Economical pump control through multiple cable probe

VEGAKON 61

Conductive limit switch for liquids for front-flush mounting

Compact level switch with partial PTFE insulation

Application area

For front-flush installation. The instrument is ideally suited as full or empty detector in pipelines.
The VEGAKON 61 is a condcutive limit switch for conductive liquids. The instrument is best suited as full and empty detector in pipelines.

Your benefit

  • Optimum cleanability through front-flush mounting
  • Maintenance-free operation through probe insensitive to buildup
  • Time and cost-saving setup without adjustment with medium

VEGAKON 66

Conductive multiple rod limit switch for liquids

Multiple rod level switch with PP insulation

Application area

With two measuring electrodes you can realise a level detection without hysteresis, with three measuring electrodes a pump or two-point control or a limit level with hysteresis.
The VEGAKON 66 is a conductive limit switch for conductive liquids. The instrument is suitable as full or empty detector in pipelines.

Your benefit

  • Reliable pump control through multiple rod probe
  • Reduced stock-keeping through exchangeable rod probes
  • High flexibility through shortenable probe