Indicating instruments

Magnetic pen for display/adjustment module PLICSCOM

Application area

The magnetic pen offers the possibility of easy operation for the display and adjustment module PLICSCOM with the option of Bluetooth/magnetic pen adjustment with closed housing lid with inspection window.

PLICSCOM

Pluggable display and adjustment module for plics® sensors

Measured value indication and adjustment of plics® sensors

Application area

Universal display and adjustment module suitable for all sensors of the VEGA plics® family, VEGABAR series 50/60/80, VEGADIF 65/85, VEGACAL series 60, VEGAFLEX series 60/80, VEGAPULS series 60, VEGASON series 60, PROTRAC as well as VEGADIS series 80.

Your benefit

  • Simple to detach, hence use also with other sensors
  • Simple and reliable adjustment of the plics® sensors through clear text indication with comprehensive graphic support
  • Minimum time expenditure through reliable function and clear, graphic-capable LC display with 4-key operation as well as integrated lighting
  • Optional possibility of wireless operation via Bluetooth with smartphone/tablet/PC as well as magnetic pen operation in case of housing lid with inspection window

PLICSLED

Pluggable display module (switching status) for plics® sensors

Display module for plics® sensors with relay output

Your benefit

  • Mininum time required for installation because no external wiring necessary
  • Clearly visible switching state indication even by strong daylight
  • Universal use
  • High protection through module integrated in plics® sensor housing

VEGADIS 176

External display

External display for 4 ... 20 mA/HART sensors, without external power supply for panel mounting

Application area

External display and adjustment module for panel mounting without external energy Application area The VEGADIS 176 is an external display and adjustment module without additional external energy. It is used for separate measured value indication of all standardized 4 … 20 mA circuits. Your benefit - Universal use through five-digit, scalable 17 mm display with backlight - Reliable function and various application possibilities thanks to a compact, robust housing with high protection rating in the front area - The low voltage drop of < 1 V allows the use in most 4 … 20 mA circuits Technical data Display:|;digital Voltage drop:|;< 1 V Signal: |;4 … 20 mA Mounting: |;panel mounting

Your benefit

  • Reliable function and wide range of application thanks to compact, rugged housing with high protection rating
  • Universal use through 5-digit, backlit, scalable 17 mm display
  • The low voltage drop of <1 V allows use in most 4 ... 20 mA circuits

VEGADIS 81

External display and adjustment unit for plics® sensors

External display and adjustment unit for VEGA sensors, optionally with Bluetooth

Application area

The VEGADIS 81 is an external, digital display and adjustment unit for all plics® sensors. The instrument is mounted in a distance of up to 50 m away from the sensor where it is easily accessible. It is directly connected to the electronics of the sensor from which it is also powered.

Your benefit

  • Reading and adjustment comfort through installation in 90° steps
  • Simple adjustment via 4 keys and clearly structured program guidance
  • Good readability of the display through clear text indication with graphic support (PLICSCOM)
  • Measured value indication and sensor adjustment in an easily accessible position
  • Optional possibility of wireless operation via Bluetooth with smartphone/tablet/PC as well as magnetic pen operation in case of housing lid with inspection window

VEGADIS 82

External display and adjustment unit for 4 … 20 mA/HART sensors

External display and adjustment unit for 4 ... 20 mA/HART sensors, optionally with Bluetooth

Application area

The VEGADIS 82 is suitable for measured value indication and adjustment of 4 … 20 mA sensors, optionally with HART protocol. The instrument can be looped in any position directly in the signal cable. It operates as pure display instrument in a 4 … 20 mA current loop. Optionally sensors with HART protocol can be operated. The instrument is particularly designed for VEGAPULS (C) 11, 21, 22, 23, 31 and VEGAWELL 52 sensors.

Your benefit

  • Time and cost savings during the parameter adjustment on site with PLICSCOM
  • Reliable and simple adjustment through clear text indication with graphic support
  • Universal use through HART standard parameters
  • Optional possibility of wireless operation via Bluetooth with smartphone/tablet/PC as well as magnetic pen operation in case of housing lid with inspection window

VEGAMET 341

Built-in controller and display instrument for level sensors

For one 4 … 20 mA sensor, front panel mounting

Application area

1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
The VEGAMET 341 controller feeds the connected 4 ... 20 mA sensor, processes the measured values and displays them. The installation housing is ideal for mounting in the control panel. A large display for data visualisation as well as a turn/push button for easy adjustment on site are integrated. With VEGAMET 341, limit values can be reliably monitored and relays, e.g. for overfill protection according to WHG, can be switched. The multifunctional instrument enables pump switching, flow measurement in open flumes or on weirs and summation. Due to its various possibilities, it is suitable for many industrial sectors as well as plant manufacturers.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 342

Built-in controller and display instrument for level sensors

For two 4 … 20 mA sensors, panel mounting

Application area

2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
The VEGAMET 342 controller feeds the connected 4 ... 20 mA sensors, processes the measured values and displays them. The installation housing is ideal for mounting in the control panel. A large display for data visualisation as well as a turn/push button for easy adjustment on site are integrated. With VEGAMET 342, limit values can be reliably monitored and relays, e.g. for overfill protection according to WHG, can be switched. It enables simple implementation of pump controls, flow measurements on open flumes and weirs, totalizers, differential, sum, average and average value calculations. Due to its versatile and universal possibilities, it is suitable for many industrial sectors as well as plant engineers.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 391

Controller and display instrument for level sensors

Optimized for the water/wastewater industry

Application area

The VEGAMET 391 controller powers any 4 … 20 mA/HART sensor, processes and displays the measured values. The VEGAMET 391 is perfectly suitable for simple control tasks in level, gauge and process pressure measurements as well as for inventory management (VMI) and remote enquiry. Comprehensive adjustment functions allow individual adaptations to the respective application. In the water/sewage water industry, the instrument impresses with special functions such as pump switching-over, flow volume measurement, tendency functions and totalizer.

Your benefit

  • Simple integration into the Intranet/Extranet through integrated Web server
  • Steady utilization of the pumps through integrated pump management
  • Completely integrated function unit for flow volume measurement

VEGAMET 841

Robust controller and display instrument for level sensors

For one 4 ... 20 mA sensor

Application area

1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 841 controller feeds the connected 4 ... 20 mA sensor, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs and totalizers. With VEGAMET 841, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Clearly arranged, readable from a distance and individually programmable display
  • Complex programming of control tasks is no longer necessary
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 842

Robust controller and display instrument for level sensors

For two 4 ... 20 mA sensors

Application area

2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 842 controller feeds the connected 4 ... 20 mA sensors, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers, difference, sum and average value calculations. With VEGAMET 842, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 861

Robust controller and display instrument for level sensors

For one 4 … 20 mA/HART sensor

Application area

1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 861 controller feeds the connected 4 ... 20 mA or HART sensor, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers and data loggers. With VEGAMET 861, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness