Switching

Capacitive

Conductive

Radar

Radiation-based

Vibration

VEGAPOINT 21

Compact capacitive limit switch

For the detection of water-based liquids

Application area

From DK > 1.5, from thread ½", universal connection G1" for hygiene adapter, M12, valve plug, transistor output, IO-Link, wireless operation, Ex and hygiene approvals
VEGAPOINT 21 is a low-cost limit switch for the detection of water-based liquids. The optional universal connection for hygiene adapters ensures reduced installation effort and leaner stock keeping and perfectly meets the requirements for hygienic processes in the food, beverage and pharmaceutical industries. It can be used without adjustment in the application. With IO-Link, it offers continuous digital data transmission.

Your benefit

  • Coloured 360° status display, adjustable
  • Easy integration into control systems through IO-Link communication
  • Low-cost limit switch with smallest installation dimensions

VEGAPOINT 23

Compact capacitive limit switch with tube extension

For the detection of water-based liquids

Application area

From DK > 1.5, from thread ½", universal connection G1" for hygiene adapter, M12, valve plug, transistor output, IO-Link, wireless operation, Ex and hygiene approvals, tube version, up to 1 m
VEGAPOINT 23 is a limit switch with remote switching point for detection of water-based liquids. The optional universal connection for hygiene adapters ensures reduced installation effort and leaner stock keeping and perfectly meets the requirements for hygienic processes in the food, beverage and pharmaceutical industries. It can be used without adjustment in the application. With IO-Link, it offers continuous digital data transmission.

Your benefit

  • Coloured 360° status display, adjustable
  • Easy integration into control systems through IO-Link communication
  • Low-cost limit switch with selectable switching point position / tube extension

VEGAPOINT 24

Compact capacitive limit switch

For the detection of sticky and adhesive media

Application area

From DK > 1.5, from thread ½", universal adapter G1* for hygiene adapter M12, valve plug, transistor output, IO-Link, wireless operation, Ex and hygiene approvals
VEGAPOINT 24 is designed for level detection of very adhesive products and can reliably detect the coverage state even with the strongest buildup due to the intelligent evaluation. The absolutely front-flush design ensures cleaning without spray shadows.

Your benefit

  • Coloured 360° status display, adjustable
  • Easy integration into control systems through IO-Link communication
  • Low-cost limit switch with smallest installation dimensions

VEGAPOINT 31

Compact capacitive limit switch

For the detection of light bulk solids

Application area

From thread ½", universal connection G1" for hygiene adapter, M12, valve plug, transistor output, IO-Link, wireless operation, hygiene approvals
VEGAPOINT 31 is a low-cost limit switch for use with light bulk solids. The optional universal connection for hygiene adapters ensures reduced installation effort and leaner stock keeping and perfectly meets the requirements for hygienic processes in the food, beverage and pharmaceutical industries. It can be used without adjustment in the application. With IO-Link, it offers continuous digital data transmission.

Your benefit

  • Coloured 360° status display, adjustable
  • Easy integration into control systems through IO-Link communication
  • Low-cost limit switch, optimized for light bulk solids

VEGASOURCE 31

Source container for reception of a gamma radiator

Application area

The VEGASOURCE 31 is used for the reception of a gamma radiator which is used as radiation source for the radation-based limit level, level and density measurements. The design of VEGASOURCE 31 offers an optimum shielding and protects the integrated gamma radiator reliably.

Your benefit

  • Reliable shielding allows use without control sections
  • Reduced space requirement and simple mounting
  • Operational reliability through pneumatic ON/OFF switching

VEGASOURCE 35

Source container for reception of a gamma radiator

Application area

The VEGASOURCE 35 is used for the reception of a gamma radiator which is used as radiation source for the radation-based limit level, level and density measurements. The VEGASOURCE 35 is designed for larger source activities, offers an optimum shielding and reliable protection of the integrated source capsule.

Your benefit

  • Reliable shielding allows use without control sections
  • Reduced space requirement and simple mounting
  • Operational reliability through pneumatic ON/OFF switching

VEGASOURCE 81

Application area

VEGASOURCE 81 is used for safe reception of a gamma emitter which is used as a radiation source for radiation-based level, density, mass flow and level measurements. The radiation is emitted undamped only in one defined direction. VEGASOURCE 81 reliably shields the environment against gamma radiation in all other directions.

Your benefit

  • Reliable shielding allows use without control sections
  • Reduced space requirement due to compact design with low weight
  • Operational reliability through electric or pneumatic ON/OFF switching

VEGASOURCE 82

Application area

VEGASOURCE 82 is used for safe reception of a gamma emitter which is used as a radiation source for radiation-based level, density, mass flow and level measurements. The radiation is emitted undamped only in one defined direction. VEGASOURCE 82 reliably shields the environment against gamma radiation in all other directions.

Your benefit

  • Operational reliability through electric or pneumatic ON/OFF switching
  • Optimum shielding allows low weight and use without control areas
  • Exceptional ON/OFF repeatability

VEGASOURCE 83

Application area

VEGASOURCE 83 is used for safe reception of a gamma emitter which is used as a radiation source for radiation-based level, density, mass flow and level measurements. The radiation is emitted undamped only in one defined direction. VEGASOURCE 83

Your benefit

  • Operational reliability through electric or pneumatic ON/OFF switching
  • Optimum shielding allows low weight and use without control areas
  • Exceptional ON/OFF repeatability

VEGASOURCE 84

Application area

VEGASOURCE 84 is used for safe reception of a gamma emitter which is used as a radiation source for radiation-based level, density, mass flow and level measurements. The radiation is emitted undamped only in one defined direction. VEGASOURCE 84 reliably shields the environment against gamma radiation in all other directions.

VEGASOURCE 85

Your benefit

  • Exceptional ON/OFF repeatability
  • Best shielding even with very high legal requirements
  • Optimum shielding even at the highest activity levels

VEGASOURCE 86

Your benefit

  • Exceptional ON/OFF repeatability
  • Best shielding even with very high legal requirements
  • Optimum shielding even at the highest activity levels