VEGATOR 256C

Controller for conductive probes

Transmission of signals of conductive probes

Application area

The VEGATOR 256C is a controller for conductive electrodes EL 1 … EL 8. Applications are simple level detections or pump controls.

Your benefit

  • Simple adjustment of the switching points via potentiometer
  • Simple installation through carrier rail mounting
  • Compact unit of voltage supply and processing of a conductive probe

VEGATRENN 141

Single channel separator for 4 … 20 m/HART sensors

Single channel , active

Application area

The single channel VEGATRENN 141 is used for galvanic separation, intrinsically safe power supply as well as signal transmission of Ex-approved 4 … 20 mA sensors in hazardous areas. The separate power supply ensures a reliable measured value transmission. VEGATRENN 141 is used in all industries als with Ex applications. The VEGATRENN 141 is suitable for bidirectional transmission of HART signals. The HART signal can be picked off via the HART communication sockets integrated in the front or the terminals. The complete HART permeability allows complete access to the sensor settings.

Your benefit

  • Simple installation though carrier rail mounting as well as detachable, coded terminals
  • Complete HART permeability enables free access to sensor settings
  • Universally applicable Ex separator for all 4 ... 20 mA/HART sensors (use in Ex area is optional)
  • Universal all-current power supply unit for supplying the device and the connected sensor

VEGATRENN 142

Separator for 4 … 20 mA/HART sensors

Double channel , active

Application area

The double channel VEGATRENN 142 is used for galvanic separation, intrinsically safe power supply as well as signal transmission of Ex-approved 4 … 20 mA sensors in hazardous areas. The separate power supply ensures a reliable measured value transmission. VEGATRENN 142 is used in all industries als with Ex applications. The VEGATRENN 142 is suitable for bidirectional transmission of HART signals. The HART signal can be picked off via the HART communication sockets integrated in the front or the terminals. The complete HART permeability allows complete access to the sensor settings.

Your benefit

  • Simple installation though carrier rail mounting as well as detachable, coded terminals
  • Complete HART permeability enables free access to sensor settings
  • Universally applicable Ex separator for all 4 ... 20 mA/HART sensors (use in Ex area is optional)
  • For auxiliary voltage 20.4 ... 34.1 V DC to supply the device and the connected sensors

VEGATRENN 151

Separator for 4 … 20 mA sensors

Single channel , passive

Application area

The single channel VEGATRENN 151 is used for galvanic separation of intrinsically safe applications as well as signal transmission of Ex-approved 4 … 20 mA sensors in hazardous areas. The separator is ideal in conjunction with controllers without own Ex approval. The VEGATRENN 151 is suitable for bidirectional transmission of HART signals. The HART signal can be picked off via the HART communication sockets integrated in the front or the terminals. The complete HART permeability allows complete access to the sensor settings.

Your benefit

  • Simple installation because no additional voltage supple required
  • Simple installation though carrier rail mounting as well as detachable, coded terminals
  • Reliable separation of intrinsically safe and non-intrinsically safe measuring circuits (use in hazardous areas is optional)

VEGATRENN 152

Separator for 4 … 20 mA sensors

Double channel , passive

Application area

The double channel VEGATRENN 152 is used for galvanic separation, intrinsically safe applications as well as signal transmission of Ex-approved 4 … 20 mA sensors in hazardous areas. The separator is ideal in conjunction with controllers without own Ex approval. The VEGATRENN 152 is suitable for bidirectional transmission of HART signals. The HART signal can be picked off via the HART communication sockets integrated in the front or the terminals. The complete HART permeability allows complete access to the sensor settings.

Your benefit

  • Simple installation because no additional voltage supple required
  • Simple installation though carrier rail mounting as well as detachable, coded terminals
  • Reliable separation of intrinsically safe and non-intrinsically safe measuring circuits (use in hazardous areas is optional)

VEGAVIB 61

Vibrating level switch for granular bulk solids

For granulated bulk solids from density 20 g/l – compact version

Application area

It detects the limit level reliably and with millimetre accuracy directly at the mounting position. The smooth surface of the vibrating rod, without sharp corners or edges, prevents bulk material from getting stuck or jammed and is easy to clean.
The VEGAVIB 61 is a level switch for granular and coarse-grained bulk solids. The VEGAVIB 61 detects reliably and accurately the min. or max. limit level. The smooth surface of the vibrating rod, without corners and edges, avoids jamming of the bulk solid and is easy to clean.

Your benefit

  • Low maintenance costs
  • Minimum time and cost expenditure thanks to simple setup without medium
  • Reliable function through product-independent switching point

VEGAVIB 62

Vibrating level switch with suspension cable for granular bulk solids

For granulated bulk solids from density 20 g/l – with cable extension

Application area

The position of the switching point can be up to 80 m away from the installation site. The smooth surface of the vibrating rod, without sharp corners or edges, prevents bulk material from getting stuck or jammed and is easy to clean.
The VEGAVIB 62 is a level switch for granular and coarse-grained bulk solids. The optimized rod design without corners and edges avoids jamming of the bulk solids and is easy to clean. The VEGAVIB 62 detects reliably and accurately the min. or max. limit level in bulk solids. The position of the switching point is specified flexibly through the length of the suspension cable.

Your benefit

  • Low maintenance costs
  • Minimum time and cost expenditure thanks to simple setup without medium
  • Reliable function through product-independent switching point

VEGAVIB 63

Vibrating level switch with tube extension for granular bulk solids

For granulated bulk solids from density 20 g/l – with tube extension

Application area

The position of the switching point can be up to 6 m away from the installation site. The smooth surface of the vibrating rod, without sharp corners or edges, prevents bulk material from getting stuck or jammed and is easy to clean.
The VEGAVIB 63 is a level switch for granular and coarse-grained bulk solids. The VEGAVIB 63 detects reliably and accurately the min. or max. limit level. The smooth surface of the vibrating rod, without corners and edges, avoids jamming of the bulk solid and is easy to clean. The position of the switching point is specified through the tube extension.

Your benefit

  • Low maintenance costs
  • Minimum time and cost expenditure thanks to simple setup without medium
  • Reliable function through product-independent switching point

VEGAVIB S61

Vibrating level switch for granular bulk solids

For granulated bulk solids from density 100 g/l

Application area

Pre-configured lengths of 150, 500, 1000 or 1500 mm available. Limited choice of electronics and approvals.
The VEGAVIB S61 is a level switch for granular and coarse-grained bulk solids. The VEGAVIB S61 detects reliably and accurately the min. or max. level. The smooth surface of the vibrating rod, without corners and edges, avoids jamming of the bulk solid and is easy to clean.

VEGAWAVE 61

Vibrating level switch for powders

For powdery and fine-grained bulk solids from density 8 g/l – compact version

Application area

It detects the limit level reliably and with millimetre accuracy directly at the mounting position. The tuning fork design is very robust and unaffected by buildup. Grain size: max. 10 mm
The VEGAWAVE 61 is a level switch for universal use in powders and fine-grained bulk solids. The level switch detects reliably and robust the min. or max. limit level. The tuning fork is ideal for use either in adhesive and abrasive products as well as in bulk solids with very low density.

Your benefit

  • Low costs for maintenance through robust design
  • Minimum time and cost expenditure thanks to simple setup without medium
  • Reliable function through product-independent switching point

VEGAWAVE 62

Vibrating level switch with suspension cable for powders

For powdery and fine-grained bulk solids from density 8 g/l – with cable extension

Application area

The position of the switching point can be up to 80 m away from the installation site. The tuning fork design is very robust and unaffected by buildup. Grain size: max. 10 mm
The VEGAWAVE 62 is a level switch for universal use in powders and fine-grained bulk solids. The level switch detects reliably and robust the min. or max. limit level. The tuning fork is ideal for use either in adhesive and abrasive products as well as in bulk solids with very low density. The position of the switching point is determined through the length of the suspension cable.

Your benefit

  • Low costs for maintenance through robust design
  • Minimum time and cost expenditure thanks to simple setup without medium
  • Reliable function through product-independent switching point

VEGAWAVE 63

Vibrating level switch with tube extension for powders

For powdery and fine-grained bulk solids from density 8 g/l – with tube extension

Application area

The position of the switching point can be up to 6 m away from the installation site. The tuning fork design is very robust and unaffected by buildup. Grain size: max. 10 mm
The VEGAWAVE 63 is a level switch for universal use in powders and fine-grained bulk solids. The level switch detects reliably and robust the min. or max. limit level. The tuning fork is ideal for use either in adhesive and abrasive products as well as in bulk solids with very low density. The position of the switching point can be determined through the length of the tube extension.

Your benefit

  • Low costs for maintenance through robust design
  • Minimum time and cost expenditure thanks to simple setup without medium
  • Reliable function through product-independent switching point