Short-stroke cylinders Series RPA

Double-effect, magnetic With hollow through rod and mounting stud Bores: 20 and 30 mm
The Series RPA short stroke cylinders are double acting actuators with aluminium hollow through rod and mounting stud. Available in two sizes, Ø 20 and Ø 30 mm, with different strokes and dimensions of the mounting stud, these actuators are equipped with the non-rotating function of the rod. The Series RPA are prepared for the mounting of magnetic sensors (Series CSD), in fact, on the external profile, along the cylinder tube, you can find sensor positioning slots. Their compact and light design together with the adopted technical solutions make these cylinders suitable to be used, combined with suction pads, in End Of Arm Tooling (EOAT) systems, especially in the sector of plastic injection moulding.

Shut-off micro-valves Series TC

2/2-way - Normally Closed (NC)
The principle of the Series TC1-V shut-off micro-valves is based on the actuation of a poppet by means of an operating pressure applied above it. The poppet, once actuated, moves away from the tightening seal, permitting the flow of the intercepted fluid. By removing the actuation pressure, the poppet repositions itself on the tightening seal by means of a spring positioned below that closes the flow of the fluid. For its realization the most suitable materials for contact with fluids were selected. The body in PPS and the FKM tightening seals guarantee full compatibility with a wide range of gaseous fluids.

SignalFire Ranger

Application area

The SignalFire Ranger is an IIoT (Industrial Internet of Things) cellular transmitter using the latest LTE CAT M1 or NB-IoT technology for level and pressure sensors. It provides battery power to the sensor and cellular data transmission to the VEGA Inventory System (VIS) in remote locations.

Your benefit

  • Simple setup and connectivity of a sensor to the cloud over cellular networks.
  • Optimized for battery life using the latest cell modern technology LTE CAT M1 or NB-IOT.
  • Cloud monitoring and alerting services through VIS hosting solution.

Silencers in 316L stainless steel Silencers

Silencers are indispensable elements for eliminating or reducing the characteristic noise of compressed air during discharge into the atmosphere. They should always be placed on the outlets of 3/2-, 5/2- or 5/3-way valves. When carrying out maintenance, silencers should be degreased using white spirit or paraffin and compressed air blown through them in the opposite direction to the direction of operation. Flow rate: is measured at an inlet pressure of 6 bar with exhaust in the atmosphere. Noise level: is measured through a test using a phonometer. Placing the phonometer one meter away from the application and at the same height for ten seconds, gives an average reading of the noise generated.

Silencers Series 29

Series: 2901 - 2903 - 2921 - 2931 - 2928 - 2929 - 2905 Ports: M5, G1/8, G1/4, G3/8, G1/2, G3/4, G1 Ø 4, 6, 8, 10, 12 mm
The silencers are indispensable elements for eliminating or reducing the characteristic noise of compressed air during discharge operations. They should always be placed on the outlets of 3/2, 5/2 or 5/3-way valves. When carrying out maintenance, the silencers should be degreased using white spirit or paraffin and compressed air blown through them in the opposite direction to operation.Flow rate: determined with inlet supply 6 bar and output in atmosphere. Noise level: determined through a test which is carried out using a phonometer. Placing the phonometer one meter away from the application at the same height for a period of ten seconds gives an average reading of the noise generated.

Simulators and calibration adapters

3 adapters for measuring the pH and redox values as well as the conductivity. Product type 10 can be used to check the operational reliability of technical pH and redox measuring equipment. With type 20 measuring amplifiers and connecting cables for electrolytic conductivity.

Single chamber orifice fitting FPD201

The FPD201 is a single- chamber orifice fitting suitable for fiscal (custody transfer) applications.  It enables the orifice plate to be inspected and / or replaced without removing the fitting itself from the pipeline.

Siphon

Application area

Siphons are used to decouple pressure transmitters from process temperatures above the specification.

Skipala DIGR-1502/E

DIGR-1502/E is a controller designed to control vibratory feeders driven by an electromagnetic coil. Parameter setting is performed directly on the control panel of the unit. The control unit can work independently or can be controlled from a PLC. The control unit enables the connection of sensors and valves to digital/analog inputs/outputs and ensures their function according to settings. The advantage of the DIGR-1502/E controller is the possibility of setting the own resonance frequency of a specific feeder, during which there is a sharp increase in the intensity of vibrations. In this way, excellent feeding results can be achieved even for components with a complicated shape or surface. The indisputable advantage of the regulator is the saving of electricity consumption compared to the triac regulator. The regulator allows a smooth change of frequency in the range of 20-120Hz with a step of 0.2Hz. It is therefore ideal for more demanding applications of bowl feeders. By finding the optimal frequency for the feeder, it facilitates and speeds up their production and deployment. The regulator has IP54 protection and can be mounted outside the switchboard. The controller includes a safely separated 24V / 4VA DC source for powering sensors and valves, and a 10V DC source for powering the analog input.

SL-VAA

Fast response and ultra-low noise analogue strain link

SL76-VDA

Strain link sensor with cariable digital amplifier