VEGA

Accessory and spare parts

Density

Flow

Interface

Level

Pressure

Signal conditioning

Switching

VEGAMET 841

Robust controller and display instrument for level sensors

For one 4 ... 20 mA sensor

Application area

1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 841 controller feeds the connected 4 ... 20 mA sensor, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs and totalizers. With VEGAMET 841, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Clearly arranged, readable from a distance and individually programmable display
  • Complex programming of control tasks is no longer necessary
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 841

Robust controller and display instrument for level sensors

For one 4 ... 20 mA sensor

Application area

1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 841 controller feeds the connected 4 ... 20 mA sensor, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs and totalizers. With VEGAMET 841, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Clearly arranged, readable from a distance and individually programmable display
  • Complex programming of control tasks is no longer necessary
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 842

Robust controller and display instrument for level sensors

For two 4 ... 20 mA sensors

Application area

2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 842 controller feeds the connected 4 ... 20 mA sensors, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers, difference, sum and average value calculations. With VEGAMET 842, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 842

Robust controller and display instrument for level sensors

For two 4 ... 20 mA sensors

Application area

2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 842 controller feeds the connected 4 ... 20 mA sensors, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers, difference, sum and average value calculations. With VEGAMET 842, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 861

Robust controller and display instrument for level sensors

For one 4 … 20 mA/HART sensor

Application area

1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 861 controller feeds the connected 4 ... 20 mA or HART sensor, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers and data loggers. With VEGAMET 861, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 861

Robust controller and display instrument for level sensors

For one 4 … 20 mA/HART sensor

Application area

1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 861 controller feeds the connected 4 ... 20 mA or HART sensor, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers and data loggers. With VEGAMET 861, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 862

Robust controller and display instrument for level sensors

For two 4 … 20 mA/HART sensors

Application area

2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 862 controller feeds the connected 4 ... 20 mA or HART sensors, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers, data loggers, difference, sum and average value calculations. With VEGAMET 862, limit values can be monitored reliably and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMET 862

Robust controller and display instrument for level sensors

For two 4 … 20 mA/HART sensors

Application area

2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
The VEGAMET 862 controller feeds the connected 4 ... 20 mA or HART sensors, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables a simple conversion of pump controls, flow measurements on open channels and weirs, totalizers, data loggers, difference, sum and average value calculations. With VEGAMET 862, limit values can be monitored reliably and relays can be switched, e.g. for an overfill protection according to WHG.

Your benefit

  • Complex programming of control tasks is no longer necessary
  • Simple and safe setup and diagnosis of measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

VEGAMIP R61

Microwave receiver for level detection of bulk solids and liquids

Microwave receiver

Application area

The simple and robust measuring system is virtually independent of the process and the chemical and physical properties of the product. Also suitable for detection of objects, such as vehicles or ships, or detection of solid materials on conveyor belts.
The VEGAMIP R61 is the receiving unit of the microwave emitter VEGAMIP T61 for level detection of bulk solids and liquids. Typical applications are the detection of bulk solids in silos, bunkers and crushers as well as of liquids in tubes and vessels. The non-contact measuring principle has no direct contact to the medium and guarantees wear and maintenance-free permanent operation.

Your benefit

  • Simple adjustment saves time and costs for setup
  • Reliable measurement even with very abrasive products
  • Reliable measurement even with changing product features

VEGAMIP R62

Microwave receiver in separate version for level detection of bulk solids and liquids

Microwave receiver, detached version

Application area

The non-contact measuring method has no direct contact with the medium and thus warranties continuous, wear and maintenance free operation. Detached version for use in poorly accessible or dangerous mounting locations.
The VEGAMIP R62 is the receiving unit of the microwave emitter VEGAMIP T61 in separate version for level detection of bulk solids and liquids. Typical applications are the detection of bulk solids in silos, bunkers and crushers as well as liquids in tubes and vessels. The non-contact measuring principle has no direct contact to the medium and guarantees wear and maintenance-free permanent operation.

Your benefit

  • Separate instrument version enables mounting in installation positions difficult to access
  • Reliable measurement even with very abrasive products
  • Reliable measurement even with changing product features

VEGAMIP T61

Microwave emitter for level detection of bulk solids and liquids

Microwave transmitter

Application area

Transmitting unit of the microwave barrier. To be used with a receiving unit of type VEGAMIP R61 or 62.
The VEGAMIP T61 is the emitting unit of the microwave barrier for level detection of bulk solids and liquids. Typical applications are the detection of bulk solids in silos, bunkers and crushers as well as of liquids in tubes and vessels. The non-contact measuring principle has no direct contact to the medium and guarantees wear and maintenance-free permanent operation.

Your benefit

  • Separate instrument version enables mounting in installation positions difficult to access
  • Reliable measurement even with very abrasive products
  • Reliable measurement even with changing product features

VEGAPASS 81

Application area

The combination of VEGAPASS 81 with VEGAFLEX enables a continuous level measurement outside the vessel. The bypass consists of a standpipe which is mounted as communicating vessel laterally to the vessel via two process fittings. This kind of mounting ensures that the level in the standpipe and the vessel are the same.