PLICSLED
Pluggable display module (switching status) for plics® sensors
Display module for plics® sensors with relay output
Your benefit
- Mininum time required for installation because no external wiring necessary
- Clearly visible switching state indication even by strong daylight
- Universal use
- High protection through module integrated in plics® sensor housing
Categories: Indicating instruments, Signal conditioning, VEGA
RELATED PRODUCTS
VEGACAL 64
Capacitive rod probe for continuous level measurement of adhesive products
Rod probe, fully FEP insulated
Application area
For conductive and non-conductive liquids. The rod measuring probe is fully insulated and especially suitable for viscous and adhesive products. A full/empty adjustment is necessary for setup.
The VEGACAL 64 is a level sensor for conductive and non-conductive liquids. The rod electrode is fully insulated and is particularly suitable for viscous and adhesive products.
Your benefit
- Reduced number of cleaning cycles through measurement insensitive to buildup
- Long lifetime and low maintenance requirement through robust mechanical construction
- Maximum utilization of the vessel because measurement over the complete probe length
VEGACAL 65
Capacitive cable probe for continuous level measurement
Cable probe, partly PTFE insulated
Application area
For measurement of bulk solids and can also be used in non-conductive liquids such as oil. A full/empty adjustment is necessary for setup.
The VEGACAL 65 is a level sensor for use in all industries. The partly insulated probe is ideal for the measurement of bulk solids and can be also used in non-conductive liquids such as for example oil. The proven mechanical construction offers high functional safety.
Your benefit
- High flexibility through shortenable probe
- Long lifetime and low maintenance requirement through robust mechanical construction
- Maximum utilization of the vessel because measurement over the complete probe length
VEGACAL 69
Capacitive double rod electrode for level measurement
Double rod probe, fully FEP insulated
Application area
For use in non-conductive vessels or corrosive liquids. The double rod probe is fully insulated and highly resistant. A full/empty adjustment is necessary for setup.
The VEGACAL 69 is a level sensor for continuous level measurement of liquids in non-conductive vessels or corrosive liquids. The double rod probe is fully insulated and highly resistant.
Your benefit
- Low mounting expenditure through compact double rod version
- Long service life and low maintenance due to high resistance materials
- Maximum utilization of the vessel because measurement over the complete probe length
VEGAFLEX 83
TDR sensor for continuous level and interface measurement of liquids
For aggressive media or extremely high hygienic requirements
Application area
PFA coated or polished sensor. Even in applications with steam, buildup, foam or condensation, the sensor delivers precise and reliable readings.
The VEGAFLEX 83 level sensor measures maintenance-free agressive liquids or liquid media with highest hygienic requirements. Even in applications with vapour, buildup, foam generation and condensation, the sensor delivers precise and reliable measured values. The VEGAFLEX 83 is the economical and ideal solution for your application.
Your benefit
- The gap-free hygienic design ensures simple and reliable cleanability
- The maintenance-free operation increases the plant efficiency
- The guided adjustment enables a simple, time-saving and reliable setup
VEGAPULS C 11
Wired radar sensor for continuous level measurement
For simple measuring tasks, IP66/IP68, Type 6P
Application area
Axial cable outlet, 4 ... 20 mA output, measuring range up to 10 m, accuracy ±5 mm, PVC cable with 10 m length
VEGAPULS C 11 is the ideal sensor for non-contact level measurement in simple applications where a high degree of protection is required. It is particularly suitable for use in water treatment, pumping stations, rain overflow basins and level monitoring. In bulk solids the sensors are used in small bulk solids silos or open containers.
Your benefit
- Exact measurement results independent of medium, process and environmental conditions
- Low-cost radar sensor for simple measurement tasks
- Maintenance-free operation due to non-contact 80 GHz radar technology