ATF3500 Series
The ATF3500 series is a liquid turbine flowmeter, as fluid flows through turbine rotor and drives it to rotate, the rotating rotor periodically cuts magnetic field line to generate electric pulse signal, which can be transmitted to output or transferred to the meter to display flow rate and totalizer. It features high accuracy, good repeatability, simple structure, low pressure loss, convenient maintenance, etc. It is ideal to measure the volume of low-viscosity liquids in closed pipes, such as tap and demineralised water, fuels, liquefied gases, light fuel oil, solvents, pharmaceutical fluids, food, etc.
Categories: ALIA, Flowmeter, Turbine Flowmeter
Features
- Designed for a wide range of liquid applications
- High measuring accuracy, regardless of the mounting position
- 4-20 mA with HART signal and pulse outputs, user selectable
- Abrasion-resistant tungsten carbide rotor shaft and bearings
- Superior materials of construction for high performance in aggressive environments
- Easily cleaned and designed to flush particulates through the turbine with the medium
- For variable use thanks to different pick-up sensors as well as a variety of connections and sizes
Specification
| Size | : | 6, 10, 15, 20, 25, 32, 40, 50, 65, 80, |
| 100, 125, 150, 200 mm | ||
| Measuring Medium | : | Liquid |
| Max. Viscosity | : | 1-60 cSt |
| Measuring Range | : | 0.1-800 m3/hr |
| Accuracy | : | +/-1.0% of reading (Standrad) |
| : | +/-0.5% of reading (Option) | |
| Repeatability | : | +/-0.2% of reading |
| Pressure Drop | : | Max. 290 mbar at 100% Measuring range |
| (Density 1 g/cm3, Viscosity 1cp) | ||
| Unit | : | m3/d, m3/hr, m3/m, m3/s, l/hr, l/m, l/s, |
| t/d, t/hr, t/m, kg/d, kg/hr, kg/m, kg/s, | ||
| g/hr, g/m, g/s, USG/m, UKG/m, bbl/d, lb/hr… |
||
| Material | ||
| Body | : | S.S. 304 / S.S. 316 |
| Bearing | : | Tungsten nickel alloy |
| Rotor | : | S.S. 420 / S.S. 2205 |
| Housing | : | Aluminum Alloy |
| Angular Connecto | : | PA66 |
| Process Connection | : | Flange (DN6 – DN200) |
| : | Thread (DN6 – DN50) | |
| : | Tri-Clamp (DN15 – DN80) | |
| Max. Pressure | : | Flange: 63 kgf/cm2 |
| : | Thread: 63 kgf/cm2 | |
| : | Tri-Clamp: 10 kgf/cm2 |
| Local Display | : | 2 or 3 lines LCD |
| : | 6 Digits flowrate | |
| : | 8 Digits totalizer | |
| Operation Temperature | : | -20~120 °C(Without Display: -20~70 °C) |
| Ambient Temperature | : | -20~60 °C |
| Current Output | : | 4-20 mA (2 wires) |
| Load | : | Rohm=(VDC-18) * 50 |
| Pulse Output | : | Scaled Pulse / Unscaled Pulse |
| Load | : | 1000-5000 Ω |
| Communication | : | HART (Compatible) |
| : | RS485 (MODBUS Protocol) | |
| Data Storage | : | Operation parameter and totalizer figures |
| are stored by EEPROM (>10 years) | ||
| Cable Entry | : | Standard: M20 Option: 1/2″ NPTF |
| : | Angular Connector DIN EN 175301-803 A | |
| Angular Connector | ||
| Ingress Protection | : | IP65 |
| Wire Cross-section | : | Max. 1.5 mm2 |
| Cable Diameter | : | 6-8 mm |
| Power Supply | : | 18-32 VDC / 18-26 VDC (without display) |
| : | Ni-MH Battery (3 years working hours) | |
| Protection Class | : | IP65 (Angular Connector) |
| : | IP67 (Aluminum Alloy Housing) | |
| : | Explosion Proof, Ex d IIC T6 |
RELATED PRODUCTS
AMC3200DF Series
The AMC3200DF Series converter features dual frequency excitation. The reduced noise and improved signal to noise ratio make it more ideal for slurry measurement in various industries such as papermaking and chemistry. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting. It is equipped with Bluetooth, HART and MODBUS communication functions.
AMF900 Series
The AMF900 Series is a flange-type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 10A to 2000 mm.
AMF900 is widely used for sewage, industrial waste, chemical, solvent, food & beverage, pulp & paper and many other industrial fluids.
AMF900 Series electromagnetic flowmeter can be used in compact or remote model with AMC Series converter of electromagnetic flowmeter.