Direct acting solenoid valves Series KN and KN High Flow

3/2-way – Normally Closed (NC) and Normally Open (NO)
3/2-way – Universal (UNI)
The Series KN directly operated solenoid valves are available also in the high flow version (KN High Flow).

Thanks to its low energy consumption and to its compact design, the KN miniaturized solenoid valve can be used in industrial and scientific applications.

General Data

TECHNICAL FEATURES
Function 3/2 NC – 3/2 NO – 3/2 UNI
Operation Direct acting poppet type
Pneumatic connections On subbase with ISO 15218 interface
Orifice diameter 0,65 … 1,1 mm
Flow coefficient kv (l/min) 0,15 … 0,39
Operating pressure 0 ÷ 3 … 7 bar
Operating temperature 0 ÷ 50 °C
Fluid Filtered compressed air, unlubricated, according to ISO 8573-1:2010 class [3:4:3], inert gas
Response time ON <10 ms – OFF <10 ms
Manual override Monostable
Installation In any position
MATERIALS IN CONTACT WITH THE MEDIUM
Body PBT
Seals NBR – FKM
Internal parts Stainless steel
ELECTRICAL FEATURES
Voltage 5 … 24 V DC – other voltages on demand
Voltage tolerance ±10%
Power consumption 1,3/0,25 … 4/1 W (inrush/holding)
Duty cycle ED 100%
Electrical connection Connector mod. 121-8…
Protection class IP50

Special versions available on demand.

Coding Example

KN 0 00 – 3 0 3 – K 1 3
KN SERIES
0 BODY DESIGN
0 = Single valve
00 NUMBER OF POSITIONS
00 = Interface
3 NUMBER OF WAYS – FUNCTIONS
3 = 3/2-way – NC
4 = 3/2-way – NO
7 = 3/2-way – UNI
0 PORTS
0 = ISO 15218 on subbase or manifold
3 ORIFICE DIAMETER
3 = Ø0,65 mm
5 = Ø1,1 mm – only for NC version with minimum pressure required to operate
6 = Ø1,1 mm
K MATERIALS
F = PBT body – FKM poppet – FKM other seals
K = PBT body – FKM poppet – NBR other seals
1 ELECTRICAL CONNECTION
1 = 90° connection with protection and led
B = In-line connection with protection and led
3 VOLTAGE – POWER CONSUMPTION
2 = 12 V DC – 1,3/0,25 W
3 = 24 V DC – 1,3/0,25 W
5 = 5 V DC – 4/1 W
7 = 12 V DC – 4/1 W
8 = 24 V DC – 4,1 W
FIXING
= Fixing screws for plastic
M = Fixing screws for metal
USE WITH OXYGEN:
= Not suitable for use with oxygen
OX2 = per utilizzo con ossigeno – livello di pulizia secondo normativa ASTM G93-03 Livello B

RELATED PRODUCTS