AVF250 Series
The AVF250 Series flowmeter is commonly used in locations that require on-site analog flow indications. The meter accurately measures small volumes / wide ranges of liquids, gases and steam.
Categories: ALIA, Flowmeter, Variable Area Flowmeter
Features
- 5 Digit Flowrate & 7 Digit Totalizer
- Integrated temperature and pressure compensation
- Local indication without auxiliary power
- 4-20 mA and scale pulse output
- Low pressure loss in gas and steam application
- Damper for Gas / Steam application
- Consistent overall length
- Heating jacket design
- Intrinsically safe & explosion proof for hazardous area
Specification
| Size | : | 15,20,25,40,50,65,80,100,125,150,200 mm |
| Measuring Range | : | Liquid _1~200000 L/hr |
| : | Gas _0.03~3000 m3/hr | |
| Turndown Ratio | : | 10:1 (20:1 Option) |
| Accuracy | : | +/-1.6% (Standard) |
| : | +/-1.0% (Option) | |
| Repeatability | : | +/-0.5% FS |
| Material | ||
| Tube & Float | : | Stainless Steel 304 |
| : | Stainless Steel 316 | |
| : | Stainless Steel 316L | |
| : | Stainless Steel + PTFE Liner | |
| Standard Pressure | : | 40 kgf/cm2 (15-50 mm) |
| : | 16 kgf/cm2 (65-200 mm) | |
| Temperature | : | -25~200 °C (Standard) |
| : | -25~100 °C (LCD Display) | |
| : | 0~80 °C (PTFE Liner) | |
| : | -80~400 °C (Option) | |
| Flange Type | : | JIS 10K / JIS 20K / JIS 40K |
| ANSI 150# / ANSI 300# / ANSI 600# | ||
| DIN PN10 / PN16 / PN25 / PN40 | ||
| Fluid Viscosity | : | 300 cP Max. |
| Communication | : | RS485 (MODBUS Protocol) |
| : | HART signal (Compatible) |
| Local Display | : | Mechanical Indicator (Standard) |
| Digit Display | : | 5 Digit Flowrate |
| : | 7 Digit Totalizer | |
| Current Output | : | 4-20 mA (2-Wire) |
| Load | : | Max. 600 Ω |
| Pulse Output | : | Open collector (Scaled pulse) |
| Rating | : | 3-30 VDC, 100 mA Max. |
| Data Storage | : | Operation parameters and totalizer |
| figures are stored by EEPROM for | ||
| more than 10 years | ||
| Limit Switches | : | 2-Wire NAMUR (For Exia / Exd) |
| 3-Wire transistor | ||
| Keypad | : | 3 Internal keys for programming |
| and display control | ||
| Ambient Temperature | : | -25~60 °C |
| Protection Class | : | IP65 |
| : | Intrinsically Safe, Eex ia IIC T5 | |
| : | Explosion Proof, Ex d IIC T6 | |
| Housing Material | : | Aluminum Alloy |
| Cable Entry | : | Standard: M20 Option: 1/2″ NPTF |
| Pressure Loss | : | 0.07-0.7 kgf/cm2 |
| Power Supply | : | 12-32 VDC |
| : | Ni-MH Battery (3 years working hours) | |
| Option | : | Temp. & Pressure compensation |
RELATED PRODUCTS
AMF500 Series
The AMF500 Series is a wafer-type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 50-200 mm.
AMF500 is widely used for tap water, waste water, food & beverage, pulp & paper and many other industrial fluids.
AMF500 Series electromagnetic flowmeter can be used in compact or remote model with AMC Series converter of electromagnetic
flowmeter.
AMF900 Series
The AMF900 Series is a flange-type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 10A to 2000 mm.
AMF900 is widely used for sewage, industrial waste, chemical, solvent, food & beverage, pulp & paper and many other industrial fluids.
AMF900 Series electromagnetic flowmeter can be used in compact or remote model with AMC Series converter of electromagnetic flowmeter.
ATF3500 Series
The ATF3500 series is a liquid turbine flowmeter, as fluid flows through turbine rotor and drives it to rotate, the rotating rotor periodically cuts magnetic field line to generate electric pulse signal, which can be transmitted to output or transferred to the meter to display flow rate and totalizer. It features high accuracy, good repeatability, simple structure, low pressure loss, convenient maintenance, etc. It is ideal to measure the volume of low-viscosity liquids in closed pipes, such as tap and demineralised water, fuels, liquefied gases, light fuel oil, solvents, pharmaceutical fluids, food, etc.
ATF80 Series
The ATF80 Series Smart Target Flowmeters revolutionize the target deflection method of measuring flow. The target displacement is precisely measured by capacitance sensors.
The resultant signal is then digitally processed via surface-mount, industrial signal processing to Produce a 4-20 mA output proportional to the volumetric flowrate. Smart Target Flowmeter is suitable for low-velocity & high-temp. Gas, steam flowrate. Re-ranging the meter is as simple as changing the target. There is no need to change the whole meter.
AUF772 Series
The AUF772 Series sanitary-type ultrasonic flowmeter adopts materials and new processes that meet the sanitary requirements of food industry. It uses stainless steel housing and clamp connection, which is easy to disassemble and clean. And it can effectively prevent pollution during using and the residues in the measuring tube.
AUF772 can be widely used in food production processes such as mineral water, soy sauce, jam, beer, juice, rice wine and milk, as well as in the fields of sanitation and chemical industry.